OPTIMA Protected Element Transducers

OPTIMA Protected Element Transducers can fitted with three different types of replaceable protective faces. Used interchangeably, these protective faces extend the use of a single transducer for flaw detection in materials having rough, uneven, abrasive, or hot surfaces. Relatively large element sizes and low-to-midrange frequencies are combined to produce high energy transducers with the high penetrating abilities.

Features - Protected Element Models are fitted with a threaded ring which retains any of three protective faces in intimate contact with the transducer element. One type of protective face is a somewhat pliable polymeric membrane used to assist coupling to rough or uneven surfaces. The wear-cap face is a short, firm polymeric delay line that can replaced after use on rough, abrasive surfaces, or where a contoured face is needed. A one-inch long heat-resistant delay line porvides protection for the element in high temperature applications (intermittent use op to 600(degree mark)F). All are readily interchangeable.

Protected-Element PDF

Freq.
MHz

Protected Element Models - Element Diameter - In

Series

0.500

0.750

1.000

1.125

0.5

General Purpose

 -------------

RHF0.56

RHF0.58

RHF0.59

Hi Gain

 -------------

RMF0.56

RMF0.58

RMF0.59

1.0

General Purpose

RHF014

RHF016

RHF018

RHF019

Hi Gain

RMF014

RMF016

RMF018

RMF019

2.25

General Purpose

RHF024

RHF026

RHF028

RHF029

Hi Gain

RMF024

RMF026

RMF028

RMF029

3.5

General Purpose

RHF034

RHF036

RHF038

 -------------

Hi Gain

RMF034

RHF036

 RMF038

 -------------

5.0

General Purpose

RHF054

RHF056

 -------------

 -------------

Hi Gain

RMF054

RMF056

 -------------

 -------------

Face
Type

Wear Caps, Membranes & Delay Lines
Element Diameter - In

0.50

0.75

1.00

1.13

Standard Wear Cap

WC4

WC6

WC8

WC9

Elastomeric Membrane*

RM4

RM6

RM8

RM9

1 Inch Delay Hi Temp

RD4

RD6

RD8

RD9

TO ORDER OPTIMA standard contact transducer, use the Model Number from the accompanying table. For a detailed description of the features of NDT Systems' GP (General Purpose), HG(High Gain), and HR (High Resolution) series transducers, see Transducer selection. Also note:

  • Unless otherwise specified, a side-mounted BNC connector will be provided.
  • Top-mounts and UHF connectors are optional and must be designed when ordering.
  • Documentation can be furnished for a small additional charge. See documentation and certification for details.
  • Cables and adaptors
  • Test blocks

Element
Diameter

Protected Dimentions - In

A

B

C

0.50

0.95

0.70

1.28

0.75

1.18

0.95

1.28

1.00

1.37

1.20

1.28

1.125

1.50

1.33

1.33

[Home] [Product List] [Thickness Gauges] [Flaw Detectors] [Bond Testers] [Transducers] [Imaging Systems] [Automotive] [What's NEW!!] [Reference] [Employment] [About Us]

NDT Systems, Inc.
17811 Georgetown Lane, Huntington Beach, CA. 92647
Phone (714) -893-2438 * Fax (714) -897-3840
Contact info@ndtsystems.com with questions or comments on NDT Systems products.