Sample Images - 007

These images are "Thumbnail" views of actual scanned images and include a short description of each. For more of s detailed view click on the image and a larger view will be displayed. The length of time to display the larger image will be longer due to its size and resolution. We think the wait will be worth it

36Pend

Ref Image 1
This is a sample of a manufactured block with several counter bored holes of varying diameters

Standard "Zoom" view of  Ref Image 1. Note the mini 'C' Scan in the upper right corner will show the outline of the zoomed view

This is a 'C' Scan example of a pipe with actual corrosion

Spreadsheet View of ref Image 1. In this view, the software displays the maximum number of data cells it can with actual data values

This is a 3 view 'C' & Dual axis 'B' scan example of a pipe with actual corrosion. Thickness displayed at cross hair intersection

Spreadsheet View of Corrosion Sample. In this view, the software displays the maximum number of data cells it can with actual data values

3D high resolution "wire frame" view of corrosion sample

This is a 3 view 'C' & Dual axis 'B' scan example of a pipe with actual erosion. Thickness displayed at cross hair intersection

Color Palette histogram of erosion sample. Higher values of a given color represent more data around that particular thickness or amplitude data

Large manufactured steel scan block. Incorporates several steps and within each step are 3 different diameter holes in flat and spherical bottom

Several Layer graphite composite test sample with manufactured defects of several sizes at various layers. Scanned with NDT Systems, Inc. NovaScope

3D View of above block in the high resolution, wire frame display mode

Several Layer graphite composite test sample in low resolution "dots" 3D mode

Several Layer graphite composite test sample in high resolution "dots" 3D mode

Several Layer graphite composite test sample with gray spectrum selected

Several Layer graphite composite test sample with red spectrum selected

Amplitude scan over bonded and riveted strucures. The 6 evenly spaced areas are the rivet areas

Several Layer graphite composite test sample with green spectrum

NDT Systems, Inc.   PLEASE NOTE: Our New Address as of Jan 2010 is:
5542 Buckingham Drive * Huntington Beach,  CA.  92649
Phone (714) 899.4638 * Fax (714) 897-3848
Contact info@ndtsystems.com with questions or comments
Copyright 2001 - 2012 NDT Systems, Inc. All rights reserved.

NI_logo-99w

NDT Systems, Inc. a Nova Instruments company